Product Errata 37
Revision Guide for AMD Family 10h Processors
41322 Rev. 3.16 February 2008
295 DRAM Phy Configuration Access Failures
Description
Under a highly specific set of asynchronous timing conditions established during cold boot (S5 to S0
transition) or resume (S4 or S3 to S0 transition), the skew between the DRAM controllers (DCTs) and
DRAM phy may lead to unreliable communication for DRAM phy configuration accesses.
Potential Effect on System
The system may hang during DRAM configuration accesses when using DCT link ganged mode
([DRAM Controller Select Low Register] F2x110[DctGangEn] = 1b), or fail DRAM training in link
ganged mode or in link unganged mode.
Suggested Workaround
Contact your AMD representative for information on a BIOS update.
Fix Planned
Yes